DATA SHEET
E64/10/50 Planar E cores and accessories
Supersedes data of September 2004 2008 Sep 01
Ferroxcube
Planar E cores and accessories
CORES Effective core parameters of a set of E cores
handbook, halfpage
E64/10/50
64.0 1.3 53.8 1.1 10.2 0.2 5.1 0.13 10.2 0.13 R0.25 max. typ.
SYMBOL (I/A) Ve Ie Ae Amin m
PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core half
VALUE 0.156 40700 79.9 519 519 100
UNIT mm-1 mm3 mm mm2 mm2 g
50.8 1
R0.64 ref. typ.
R0.81 ref. typ.
CBW415
Dimensions in mm.
Fig.1 E64/10/50.
Effective core parameters of an E/PLT combination SYMBOL (I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of plate VALUE 0.136 35500 69.7 519 519 78 UNIT mm-1 mm3 mm mm2 mm2 g
handbook, halfpage
64 1.3 5.08 0.13
Ordering information for plates GRADE 3C90 3C92 3C93 3C94 3C95 3F3 3F4 TYPE NUMBER PLT64/50/5-3C90 PLT64/50/5-3C92 PLT64/50/5-3C93 PLT64/50/5-3C94 PLT64/50/5-3C95 PLT64/50/5-3F3 PLT64/50/5-3F4
Dimensions in mm.
50.8 1
R0.64 ref. typ.
CBW416
Fig.2 PLT 64/50/5.
2008 Sep 01
2
Ferroxcube
Planar E cores and accessories
E64/10/50
Core halves for use in combination with an E core AL measured in combination with a non-gapped core half, clamping force for AL measurements, 100 30 N, unless stated otherwise. GRADE 3C90 AL (nH) 630 3%(1) 1000 3%(1) 1600 5% 2500 10% 3150 10% 14640 25% 3C92 3C93 3C94 11200 25% 13300 25% 630 3%(1) 1000 3%(1) 1600 5% 2500 10% 3150 10% 14640 25% 3C95 3F3 17890 25% 630 3%(1) 1000 3%(1) 1600 5% 2500 10% 3150 10% 13300 25% 3F4 630 3%(1) 1000 3%(1) 1600 5% 2500 10% 3150 10% 6960 25% Note 1. Measured in combination with an equal-gapped core half, clamping force for AL measurements, 100 30 N. e 78 124 199 310 391 1820 1390 1650 78 124 199 310 391 1820 2190 78 124 199 310 391 1650 78 124 199 310 391 860 TOTAL AIR GAP (m) 1100 660 385 225 170 0 0 0 1100 660 385 225 170 0 0 1100 660 385 225 170 0 1100 660 385 225 170 0 TYPE NUMBER E64/10/50-3C90-E630-E E64/10/50-3C90-E1000-E E64/10/50-3C90-A1600-E E64/10/50-3C90-A2500-E E64/10/50-3C90-A3150-E E64/10/50-3C90 E64/10/50-3C92 E64/10/50-3C93 E64/10/50-3C94-E630-E E64/10/50-3C94-E1000-E E64/10/50-3C94-A1600-E E64/10/50-3C94-A2500-E E64/10/50-3C94-A3150-E E64/10/50-3C94 E64/10/50-3C95 E64/10/50-3F3-E630-E E64/10/50-3F3-E1000-E E64/10/50-3F3-A1600-E E64/10/50-3F3-A2500-E E64/10/50-3F3-A3150-E E64/10/50-3F3 E64/10/50-3F4-E630-E E64/10/50-3F4-E1000-E E64/10/50-3F4-A1600-E E64/10/50-3F4-A2500-E E64/10/50-3F4-A3150-E E64/10/50-3F4
2008 Sep 01
3
Ferroxcube
Planar E cores and accessories
Core halves for use in combination with a plate (PLT) AL measured in combination with a plate (PLT), clamping force for AL measurements, 100 30 N. GRADE 3C90 AL (nH) 630 3% 1000 3% 1600 5% 2500 10% 3150 10% 16540 25% 3C92 3C93 3C94 12700 25% 15050 25% 630 3% 1000 3% 1600 5% 2500 10% 3150 10% 16540 25% 3C95 3F3 20150 25% 630 3% 1000 3% 1600 5% 2500 10% 3150 10% 15050 25% 3F4 630 3% 1000 3% 1600 5% 2500 10% 3150 10% 7920 25% e 78 124 199 310 391 1790 1370 1630 78 124 199 310 391 1790 2150 78 124 199 310 391 1630 78 124 199 310 391 860 AIR GAP (m) 1100 660 385 225 170 0 0 0 1100 660 385 225 170 0 0 1100 660 385 225 170 0 1100 660 385 225 170 0
E64/10/50
TYPE NUMBER E64/10/50-3C90-A630-P E64/10/50-3C90-A1000-P E64/10/50-3C90-A1600-P E64/10/50-3C90-A2500-P E64/10/50-3C90-A3150-P E64/10/50-3C90 E64/10/50-3C92 E64/10/50-3C93 E64/10/50-3C94-A630-P E64/10/50-3C94-A1000-P E64/10/50-3C94-A1600-P E64/10/50-3C94-A2500-P E64/10/50-3C94-A3150-P E64/10/50-3C94 E64/10/50-3C95 E64/10/50-3F3-A630-P E64/10/50-3F3-A1000-P E64/10/50-3F3-A1600-P E64/10/50-3F3-A2500-P E64/10/50-3F3-A3150-P E64/10/50-3F3 E64/10/50-3F4-A630-P E64/10/50-3F4-A1000-P E64/10/50-3F4-A1600-P E64/10/50-3F4-A2500-P E64/10/50-3F4-A3150-P E64/10/50-3F4
2008 Sep 01
4
Ferroxcube
Planar E cores and accessories
Properties of core sets under power conditions B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 320 320 370 370 320 320 320 320 320 320 300 300 250 250 f = 100 kHz; B = 100 mT; T = 100 C 4.8 4.2 3.6 3.2 3.6 (1) 3.2 (1) 3.6 3.2 - - 4.8 4.2 - - CORE LOSS (W) at f = 100 kHz; B = 200 mT; T = 25 C - - - - - - - - 25.6 22.4 - - - - f = 100 kHz; B = 200 mT; T = 100 C - - 25 23 25(1) 23(1) 25 23 24.4 21.3 - - - -
E64/10/50
f = 400 kHz; B = 50 mT; T = 100 C - - - - - - - - - - 7.8 6.8 - -
E+E64-3C90 E+PLT64-3C90 E+E64-3C92 E+PLT64-3C92 E+E64-3C93 E+PLT64-3C93 E+E64-3C94 E+PLT64-3C94 E+E64-3C95 E+PLT64-3C95 E+E64-3F3 E+PLT64-3F3 E+E64-3F4 E+PLT64-3F4
Measured at 140 C.
1.
Properties of core sets under power conditions (continued) B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 250 250 f = 500 kHz; B = 50 mT; T = 100 C - - CORE LOSS (W) at f = 500 kHz; B = 100 mT; T = 100 C - - f = 1 MHz; B = 30 mT; T = 100 C 12 10.5 f = 3 MHz; B = 10 mT; T = 100 C 20 17
E+E64-3F4 E+PLT64-3F4
2008 Sep 01
5
Ferroxcube
Planar E cores and accessories
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
E64/10/50
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
6


▲Up To Search▲   

 
Price & Availability of E64-3C90-A3150-E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X